Skip to main content Skip to search Skip to main navigation
Menu

Capillary columns GC BPX608

Description
35% Phenyl Polysilphenylene-siloxane. For environmental analyses, EPA 608, pesticides and herbicides. Suitable replacement for: DB-608, Rtx-35, SPB-608, HP-35, ZB-35.

Properties
Film thickness: 0.4 µm
Int. Ø: 0.32 mm
Length: 25 m
Manufacturer Article Number: 054823
Max. temperature programme: 370 °C
Temperature max isotherm: 360 °C
Skip product gallery

Similar products

GC Capillary columns HYDRODEX β-6TBDM
HYDRODEX cyclodextrin phases for enantiomer separationHeptakis-(2,3-di-O-methyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for γ-lactones, cyclopentanones, terpenes, esters, tartrates.Max. temperature for isothermal operation: 230 °CMax. temperature for short isotherms in a temperature programme: 250 °C
From CHF 1,976.00*

GC Capillary columns HYDRODEX β-TBDAC
HYDRODEX cyclodextrin phases for enantiomer separationHeptakis-(2,3-di-O-acetyl-6-O-t-butyldimethyl-silyl)-β-cyclodextrin. Phase diluted with optimised polysiloxane recommended for alcohols, esters, ketones, aldehydes, δ-lactones.Max. temperature for isothermal operation: 220 °CMax. temperature for short isotherms in a temperature programme: 240 °C
From CHF 1,814.80*

Optima® FFAP capillary columns for GC
polyethylene glycol 2-nitroterephthalateclose equivalent USP G25 / G35polar phaserecommended for FAME, free carboxylic acidssimilar phases: Permabond FFAP , DB-FFAP, HP-FFAP, CP-Sil 58 CB, 007-FFAP, CP-FFAP CB, Nukolfor columns with 0.10 to 0.32mm ID the max. temperature for isothermal operation is 250°C, the max. temperature for short isotherms in a temperature programme is 260°C for 0.53mm ID columns the max. temperatures are 220 and 240°C, resp.Custom-made columns to your specifications on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.Additionally, we supply the corresponding test mixture with each column.
From CHF 436.80*

Optima® 5 Amine GC capillary columns for amine separation
especially deactivated for the analysis of polyfunctional amines such as ethanolamines, amino-functionalised diols and similar compounds, which are important base materials in industrial chemistry, and shows strong tailing on standard-deactivated columns; similar phases: Rtx-5 Amine, PTA-5; USP G27 / G36; improved linearity for analyses of active components at trace levels: no amine absorptions even for aliphatic and aromatic amines at concentrations of 100 pg/peak; tested with the Optima® Amine test mixture, which among others also contains diethanolamine and propanol-pyridine (this test mixture is supplied with each column). Max. temperature for isothermal operation: 300°C, max. temperature for short isotherms in a temperature programme: 320°C.
From CHF 898.60*

Capillary, phenyl deactivated fused silica
Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.
From CHF 193.00*

Capillary, methyl deactivated fused silica
Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.
From CHF 83.50*

Capillary columns GC BPX-BIOD6584
Optimised for specified ASTM D6584 biodiesel methods.
Price on request

Capillary columns GC BP1
100% Dimethyl Polysiloxane. General purpose GC column for all routine analyses such as hydrocarbons, aromatics, pesticides, phenol, herbicides and amines. Suitable replacement for: DB-1, DB-Petro, HP-1, HP-1MS, Rtx-1, Ultra-1, SPB-1, SPB-1 Sulfur, Petrocol DH, CP-Sil 5CB, VB-1, ZB-1, VF-1ms.Low bleedNon-polar
From CHF 585.00*

Capillary columns GC BP10
14 % Cyanopropylphenyl Polysiloxane. For analysis of organochlorine pesticides. Suitable replacement for: DB-1701, Rtx-1701, SPB-7, HP-1701, CP-Sil 19CB, 007-1701, PE-1701, SP-1701.Low bleedHighly inertAble to be solvent rinsed
From CHF 1,028.00*

Capillary columns GC BPX35
35 % Phenyl Polysilphenylene-siloxane. Suitable Replacement for: DB-35, DB-35ms, Rtx-35, HP-35, HP-35MS, SPB-35, MDN-35.Very low bleedInertMid polarity columnEquivalent to USP phase G42High temperatureAble to be solvent rinsed
From CHF 629.00*