Handheld photometers for use in a wide range of areas such as process control, mobile water testing or wine industry. Easy operation with menu driven, user guidance. Just like the standard version of pHotoFlex® STD plus full electrochemical pH-and ORP measurement via electrodes. This allows also the measurement of the parameters NH3 and CO2.

  • pH 0 to 16.00 (±0.01) for Standard-DIN pH-electrodes with automatic temperature compensation ATC and automatic buffer recognition

  • Smart cuvette adapter: holds 28 mm or 16 mm round cuvettes with height 91 to 104 mm; to be used with a variety of different test types

  • Optics: LED's with filters

  • Concentration, Absorption, Transmission

  • Methods can be downloaded from the Internet

  • 100 user defined routines

  • 1000 data sets

  • RS 232 interface

  • 1 to 3 point calibration

  • Incl. calibration interval and calibration protocol

Scope of supply: Handheld photometer, 1 x empty cuvette 16 mm, 2 x empty cuvette 28 mm, batteries, operating manual

Properties
Accuracy: 2 nm
Accuracy: ±2 nm
Battery/rechargeable battery: 4 x 1.5 V, AA
Depth: 236 mm
Designation ANSI: AA
Dimensions (WxDxH): 86 x 236 x 117 mm
Height: 117 mm
IP code: IP 67
Illuminants: LED
Manufacturer Article Number: 251100
Max. voltage battery/rechargeable battery: 1.5 V
No. of batteries/rechargeable batteries: 4
Photometric measuring range: -2.000 ... 2.000, 1 ... 150 %T
Type: pHotoFlex® pH
Type of auxiliary energy: Battery/rechargeable battery
Wavelength: 436/517/557/594/610/690 nm
Width: 86 mm
Skip product gallery

Accessories

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test protocols
A: Stored in photoLab® S6, S12, photoLab® 6000 Serie and photoLab® SpektralB: Stored in photoLab® S12, photoLab® 6000 Serie and photoLab® SpektralC: Stored in photoFlex® and photoFlex® Turb®Reagent-free tests:Cu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and UV-VIS photoLab® 6600 (254/436nm)Further tests on demand, range information is based on max. area and can also be smaller for photoFlex®.
From CHF 99.80*

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
LabStation
LabStation with LSdata software for easy data evaluation. The rechargeable battery is included in the delivery.direct export to MS-ExcelGLP-conform data transfercalibration curve calculationadjustment between meter and PC
From CHF 716.00*

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test programs
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Serie and photoLab® SpectralB: Stored in photoLab® S12, photoLab® 6000/7000 Serie and photoLab® SpectralC: Stored in photoFlex® STD, photoFlex® pH and photoFlex® TurbD: Stored in photoLab® 6000/7000 seriesReagent-free tests:COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outletsCu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for pHotoFlex®.
Price on request
Skip product gallery

Set

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Handheld photometer pHotoFlex® pH Field case set
Handheld photometers for use in a wide range of areas such as process control, mobile water testing or wine industry. Easy operation with menu driven, user guidance. Just like the standard version of pHotoFlex® STD plus full electrochemical pH-and ORP measurement via electrodes. This allows also the measurement of the parameters NH3 and CO2.pH 0 to 16.00 (±0.01) for Standard-DIN pH-electrodes with automatic temperature compensation ATC and automatic buffer recognitionSmart cuvette adapter: holds 28 mm or 16 mm round cuvettes with height 91 to 104 mm; to be used with a variety of different test typesOptics: LED's with filtersConcentration, Absorption, TransmissionMethods can be downloaded from the Internet100 user defined routines1000 data setsRS 232 interface1 to 3 point calibrationIncl. calibration interval and calibration protocolScope of supply: Handheld photometer in field case with table insert, 0.500 to 5 ml pipette, pH electrode SenTix® 41, technical buffer solution 7.00 and 4.01, 50 ml KCl, 16 mm zero cuvette, waterproof quick guide with all programmed test sets, microfibre cloths, LSdata PC software, PC connection cable AK 540/B, screwdriver, 50 ml measuring beaker, 5 x 28 mm cuvettes, batteries, operating manual
From CHF 4,131.00*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Digestion Reagents for Photometer photoLab® and pHotoFlex®
For water analysis and electric plating to capture total nitrogen and heavy metals besides COD, total phosphorus.Comfortable with reagent presentation in round cuvettesQuick preparation of digestion
From CHF 164.00*

Cells for Photometer photoLab®
Cuvettes for photometric routine and water analytics in the UV-VIS and VIS range. Cells with matt side surface are suitable for the automatic cell detection of the photoLab® filter and spectral photometer. The glass and quartz cuvettes have a marking in order to place the cuvettes into the photometer in the same direction for an even higher precision.Automatic cell detectionGlass and quartz cells with marking for higher precisionHigh quality optical glass for VISHigh quality quartz glas for UV-VIS
From CHF 95.20*

Photometer system MultiDirect
With Dual Beam Technology. The MultiDirect is a modern, microprocessor-controlled photometer with ergonomically designed keypad and large-format graphic display. It is equipped with a wide range of pre-programmed methods (e.g. ammonia, COD, phosphate) based on the proven range of Lovibond® tablet reagents, liquid reagents, vial tests and powder reagents. The calibration and software-supported control options mean that the unit is also suitable for use as a testing instrument. The seven standard rechargeable batteries (supplied) ensure easy mobile use.Wide range of pre-programmed methodsLarge, graphics displayRS232 interfaceSuitable for use with standard rechargeable batteriesUpdates for new methods and languages via the Internet1000 data set memoryCustom method recall is also possibleScope of supply: MultiDirect, ready-to-use incl. 7 x rechargeable batteries and battery charger for 100 - 240V, 3 each 24mm and 16mm cuvettes, 16mm cuvette adapter, 3 x syringes, 1 x 100ml plastic beaker and case with waterproof insert. Without reagents and without battery (please order separately).Verification Standard Kit: The verification standard kit for the MultiDirect is designed to reassure the user about the accuracy and the reliability of the results. The shelf life of the standard kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Measurements are taken in mAbs.Specifications Optics: Dual-Beam Technology, High-quality Interference FiltersMeasuring time: Power supply:approx. 10 seconds 7 Ni-MH-battery pack (1.5V AA), charged in the unit using external power packDimensions (W x D x H): Ambient operating conditions: Approval:265mm x 70mm x 195mm up to max 90 % humidity (non condensing), approx. 5 ... 40 °C CEWavelengths:430/ 530/ 560/ 580/ 610/ 660nm
From CHF 2,064.00*

Handheld photometer pHotoFlex® pH Field case set
Handheld photometers for use in a wide range of areas such as process control, mobile water testing or wine industry. Easy operation with menu driven, user guidance. Just like the standard version of pHotoFlex® STD plus full electrochemical pH-and ORP measurement via electrodes. This allows also the measurement of the parameters NH3 and CO2.pH 0 to 16.00 (±0.01) for Standard-DIN pH-electrodes with automatic temperature compensation ATC and automatic buffer recognitionSmart cuvette adapter: holds 28 mm or 16 mm round cuvettes with height 91 to 104 mm; to be used with a variety of different test typesOptics: LED's with filtersConcentration, Absorption, TransmissionMethods can be downloaded from the Internet100 user defined routines1000 data setsRS 232 interface1 to 3 point calibrationIncl. calibration interval and calibration protocolScope of supply: Handheld photometer in field case with table insert, 0.500 to 5 ml pipette, pH electrode SenTix® 41, technical buffer solution 7.00 and 4.01, 50 ml KCl, 16 mm zero cuvette, waterproof quick guide with all programmed test sets, microfibre cloths, LSdata PC software, PC connection cable AK 540/B, screwdriver, 50 ml measuring beaker, 5 x 28 mm cuvettes, batteries, operating manual
From CHF 4,131.00*