Properties
Connection plug: S7 plug head
Diaphragm: Platinum wire
Electrolyte: KCl 3 mol/l
Manufacturer Article Number: 285102019
Material sensor: Platinum
Material shaft: Glass
Max. temperature: 100 °C
Min. temperature: -5 °C
Shaft length: 120 mm
Shaft Ø: 12 mm
Shape sensor: Pin
Temperature: -5 ... 100 °C
Temperature sensor: Without
Type: ScienceLine Pt 62
UNSPSC: 41-11-56-04
Skip product gallery

Accessories

Xylem Analytics Germany (SI)

Xylem Analytics Germany (SI)
Cable combinations
For BlueLine pH electrodes, ScienceLine, IoLine and TopLine.Cable length: 1 m coaxial cable.
From CHF 73.30*
Skip product gallery

Similar products

ORP electrodes SenTix® ORP, analogue
With glass shaft, Ag/AgCl reference system, connections for AS/DIN, AS/DIN-3, AS/BNC, S7 plug head.
From CHF 256.00*

Combined redox electrodes
DMi140-SC: Combined platinum ring redox electrode. For titrations with a change of the pH value, e.g. oxidation with potassium permanganate, copper determination with iodine, back titration with thiosulfate. With S12 screw cap and ARGENTHAL™ reference system. Plug & Play functionality.DMi141-SC: Combined silver ring electrode for argentometric titrations, determination of halides, sulfides and mercaptanes in aqueous media. Also suitable for determination of salt and silver content. With S12 screw cap and ARGENTHAL™ reference system. Plug & Play functionality.DM143-SC: Double pin platinum electrode for electrochemical titrations, e.g. water determination acc. to Karl Fischer, bromine number determination and sulfur dioxide determination in aqueous media. With S7 screw cap and ARGENTHAL™ reference system.DMi144-SC: Combined platinum ring redox electrode. For titrations with a change of the pH value, especially designed for COD determination with the Rondo 20 COD rack. With Plug & Play functionality and ARGENTHAL™ reference system.DMi145-SC: Combined silver ring electrode for argentometric titrations, determination of halides, sulfides and mercaptanes in aqueous media. Also suitable for determination of salt and silver content. With Plug & Play functionality and ARGENTHAL™ reference system.DMi148-SC: Combined silver ring electrode for argentometric titrations without a change of the pH value. For determination of halides, cyanides, sulfides and mercaptanes in mineral oil and bioethanol.
From CHF 645.00*

Redox (ORP) electrodes TopLine
ORP combination electrode with PEEK shaft and labyrinth reference element (LoopRef).
From CHF 481.00*

IDS ORP electrodes SenTix® ORP-T 900
Universel ORP electrodes with platinum disc for laboratory applications.
From CHF 315.00*

Combined redox electrodes InLab®
Redox combination electrodes for measuring the oxidation/reduction potential in aqueous solutions. The signal is generated on the surface of the indicator electrode by an electron exchange with the oxidation/reduction system of the measured medium. Without temperature sensor. With Safelock™ end ring for easy refilling of the reference electrolyte and complete sealing in closed position. For use with a wide variety of measuring instruments.InLab® Redox: For general purpose. With platinum ring indicator electrodeInLab® Redox Flow: For emulsions, wastewater analysis and general purpose. With movable ground joint junction and platinum ring indicator electrodeInLab® Redox L: For large samples. With platinum ring indicator electrodeInLab® Redox Au: Combined redox electrode with gold ring indicator electrodeInLab® Redox Ag: Combined redox electrode with silver ring indicator electrodeInLab® Redox Micro: For small samples. With platinum ring indicator electrodePlease order connection cable separately.
From CHF 374.00*

IDS ORP electrode SenTix® Rx-T 900
Digital ORP electrode with plastic shaft and gel filling for mobile field measurements.
From CHF 419.00*

Metal (ORP) electrodes ScienceLine Pt 6280
With glass shaft, pH glass membrane reference system and plug head.
From CHF 463.00*

ORP electrodes SenTix® Ag, analogue
With glass shaft, Ag/AgCl reference system, connections for AS/DIN, AS/DIN-3, AS/BNC and S7 plug head.
From CHF 452.00*

ORP electrode SensoLyt® ORP 900-P
Pressure resistant IDS platinum ORP electrode for depth measurement. With temperature sensor NTC 30 kOhm. Wireless-ready or connetion to AS/IDS cable. Pressure resistant up to 10 bar.
From CHF 1,047.00*

Metal (ORP) electrodes ScienceLine Pt 61
With glass shaft, pH glass membrane reference system and plug head.
From CHF 479.00*