Skip to main content Skip to search Skip to main navigation
Menu

Photometer MD50

Description
Scope of supply: Photometer, 3 x 24 mm round glass cuvettes with lid and sealing ring, screwdriver, 3 x stirring rods, 10 ml syringe, cleaning brush, USB-C to USB-A cable, carrying case, 2 x AA batteries, operating instructions, reagents (depending on variant)

Hazardous Substance Data
GHS
Signal word
Gefahr
H-Satz
H372
P-Satz
P264, P314
SDS
Link
Properties
Battery/rechargeable battery: 2 x AA
Depth: 155 mm
Description: Chlorine dioxide, powder reagents
Designation ANSI: AA
Dimensions (WxDxH): 76 x 155 x 45 mm
GHS: GHS08
Height: 45 mm
IP code: IP 67
Manufacturer Article Number: 280125
Max. permitted ambient temperature: 50 °C
Max. relative humidity rate: 95 %
Measuring range: 0.04 ... 3.8 mg/l ClO2
Min. permitted ambient temperature: 5 °C
No. of batteries/rechargeable batteries: 2
Permitted ambient temperature: 5 ... 50 °C
Type: MD50
Type of auxiliary energy: Battery
Width: 76 mm
Skip product gallery

Accessories

Tintometer GmbH

Tintometer GmbH
Accessories for Lovibond® photometers
From CHF 4.20*

Tintometer GmbH

Tintometer GmbH
Cuvettes for photometers
From CHF 5.70*

Tintometer GmbH

Tintometer GmbH
Cuvette stand, acrylic glass
Cuvette stand for 6 round cuvettes with a diameter of 24 mm. The cuvettes can be placed safely without slipping or tipping over. The transparent acrylic glass allows to observe changes and colour changes unobstructed.
From CHF 38.40*

Tintometer GmbH

Tintometer GmbH
USB-C cable
USB-C cable for easy data transmission to a PC.
From CHF 39.10*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Accessories NANOCOLOR®
*additional cable required**additional mains adapter required
From CHF 19.20*

Tube tests NANOCOLOR® Ammonium
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 119.10*

Accessories NANOCOLOR®, Membrane Filtration
Turbidity elimination before photometric analysis (without digestion). Sample preparation set: 2 syringes 20 ml, 25 CHROMAFIL® membrane filtersMembrane filters CHROMAFIL® without accessories* with glass fiber pre-filter, retention of coarse particles without clogging.
From CHF 146.50*