Skip to main content Skip to search Skip to main navigation
Menu

Photometer NANOCOLOR® VIS II / NANOCOLOR® UV/VIS II

Description
As complete spectrophotometers, the NANOCOLOR® VIS II and NANOCOLOR® UV/VIS II meet all requirements of your daily laboratory work. They come with the well-known barcode technology for NANOCOLOR® tube tests for fast measurements. Besides, they offer the possibility of extensive CIE-conform color measurements and scan-performance in real time. In addition to turbidity measurements, the devices offer comprehensive and free of charge brewery analysis according to MEBAK.

NANOCOLOR® VIS II and NANOCOLOR® UV/VIS II reduce the complexity of your daily laboratory work with easy menu guidance and icon-based procedures of the cuvette tests stored in the instrument. The clear result window enables an easy assignment of sample information to the measurement result. The step-by-step menu guidance for the calibration of special methods creates a simple entry level into user specific analytics even for inexperienced users.

Scope of delivery: Spectrophotometers, the NANOCOLOR® VIS II or NANOCOLOR® UV/VIS IIincl. manual (Quickstart guide), protective covering, power cable, USB cable, USB stick, calibration cuvette, touchpen, cleaning cloth and certificate


Specifications
Optical System:
Monochromator
Display:
10.1" HD display, anti-reflective cover glass with projective-capacitive touch screen (PCAP) and background LED lighting
Photometric accuracy:
0.005 E at 0.0 - 0.5 E; 1 % at 0.5 - 2.0 E
Wavelength range NANOCOLOR® VIS II: NANOCOLOR® UV/VIS II:
320 - 1100 nm 190 - 1100 nm
Wellenlängengenauigkeit:
±1 nm
Lichtquelle:
Halogen lamp
Speicher:
16 GB Micro SDHC card, 5000 measured data sets / spectra, GLP conform
Schnittstellen:
LAN, 2 x USB (Host), 1 x USB (Function) and RS 232
Netzanschluss NANOCOLOR® VIS II NANOCOLOR® UV/VIS II
12 V DC 3A 110 13240 V, ~50/60 Hz
Properties
Dimensions mm: 400 x 440 x 170 mm
Manufacturer Article Number: 919600.1
Type: NANOCOLOR® UV/VIS II
Weight kg: 6.5
Skip product gallery

Other customers also bought

HACH LANGE GmbH

HACH LANGE GmbH
Spectrophotometer DR 3900
High-performance, microprocessor driven VIS spectrophotometer with RFID technology for sample identification and tracing when using cuvette tests. Suitable for water analytics and user applications. Device includes several preconfigured application programs as well as all HACH LANGE standard test methods. Extensive, user-defined applications can be programmed. Type and expiry date of cuvette tests are identified automatically. The user is guided through the complete measuring process via touch screen.Compact and easy to useRFID sample identificationSingle or multi wavelength modeMeasurement of concentration, extinction or %-transmissionOut-of-limit value alarmFor 13 mm round cuvettes and 10/50 mm rectangular cuvettesCreation of reports and statistical evaluations7" colour touch screenBidirectional data transfer via Ethernet or USB stickMethods are updated via RFID moduleSpecificationsOptical system:Reference beam technology, spectralWavelength range: Bandwidth:320…1100 nm 5 nmWavelength resolution: Wavelength accuracy:1 nm ±1.5 nmWavelength repeatabiliy: Photometric linearity:±0,1 nm 0.5 % to 2 E, 1 % 2 E with neutral glass at 546 nmPhotometric accuracy: Lamp type:5 mE at 0.0…0.5 E, 1 % at 0.5…2.0 E Tungsten lampDimensions (W x D x H): Weight: Protection class:350 x 255 x 151 mm 4200 g IP 30Operating temperature: Relative humidity:10…40 °C 80 % rhPower supply:110…240 V, 50/60 Hz
From CHF 8,149.00*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Photometer system MultiDirect
With Dual Beam Technology. The MultiDirect is a modern, microprocessor-controlled photometer with ergonomically designed keypad and large-format graphic display. It is equipped with a wide range of pre-programmed methods (e.g. ammonia, COD, phosphate) based on the proven range of Lovibond® tablet reagents, liquid reagents, vial tests and powder reagents. The calibration and software-supported control options mean that the unit is also suitable for use as a testing instrument. The seven standard rechargeable batteries (supplied) ensure easy mobile use.Wide range of pre-programmed methodsLarge, graphics displayRS232 interfaceSuitable for use with standard rechargeable batteriesUpdates for new methods and languages via the Internet1000 data set memoryCustom method recall is also possibleScope of supply: MultiDirect, ready-to-use incl. 7 x rechargeable batteries and battery charger for 100 - 240V, 3 each 24mm and 16mm cuvettes, 16mm cuvette adapter, 3 x syringes, 1 x 100ml plastic beaker and case with waterproof insert. Without reagents and without battery (please order separately).Verification Standard Kit: The verification standard kit for the MultiDirect is designed to reassure the user about the accuracy and the reliability of the results. The shelf life of the standard kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Measurements are taken in mAbs.Specifications Optics: Dual-Beam Technology, High-quality Interference FiltersMeasuring time: Power supply:approx. 10 seconds 7 Ni-MH-battery pack (1.5V AA), charged in the unit using external power packDimensions (W x D x H): Ambient operating conditions: Approval:265mm x 70mm x 195mm up to max 90 % humidity (non condensing), approx. 5 ... 40 °C CEWavelengths:430/ 530/ 560/ 580/ 610/ 660nm
From CHF 2,064.00*

Tube tests NANOCOLOR® Chlorine / Chloride
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 53.10*

Tube tests NANOCOLOR® Cyanide
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 108.70*