Skip to main content Skip to search Skip to main navigation
Menu

Photometer photoLab® and photoFlex®, stored test programs

Description
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Series and photoLab® Spectral
B: Stored in photoLab® S12, photoLab® 6000/7000 Series and photoLab® Spectral
C: Stored in photoFlex® STD, photoFlex® pH and photoFlex® Turb
D: Stored in photoLab® 6000/7000 series

Reagent-free tests:
COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outlets
Cu - copper plating bath, 690nm, 820nm - copper plating bath - B
CrO3 - chromium plating bath - chromium plating bath - B
Ni - nickel plating bath - nickel plating bath - B
HZ - Hazen colour - Hazen colour - B
IFZ - iodine number, 340nm, 455nm - iodine number - B
m-1 (DFZ) - colouring - FB445 - B, C
m-1 (DFZ) - colouring - FB525 - A, C
m-1 (DFZ) - colouring - FB620 - B, C
FAU - turbidity 620 - T620 - B
E - extinction - extinction - A, B, C
SAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)

Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for photoFlex®.

All stored test sets for the photoLab
® and photoFlex® photometers can be found in our online shop.
Ordering information for all the articles described above and for other articles can be found online.

Hazardous Substance Data
SDS
Link
Properties
Description: Copper, Cu
For: A, C
Manufacturer Article Number: 250408
Measuring range mg / l: 0.05 - 8.00
No. of determinations: 25
Type: 14553
Skip product gallery

Other customers also bought

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test programs
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Serie and photoLab® SpectralB: Stored in photoLab® S12, photoLab® 6000/7000 Serie and photoLab® SpectralC: Stored in photoFlex® STD, photoFlex® pH and photoFlex® TurbD: Stored in photoLab® 6000/7000 seriesReagent-free tests:COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outletsCu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for pHotoFlex®.
Price on request

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test protocols
A: Stored in photoLab® S6, S12, photoLab® 6000 Serie and photoLab® SpektralB: Stored in photoLab® S12, photoLab® 6000 Serie and photoLab® SpektralC: Stored in photoFlex® and photoFlex® Turb®Reagent-free tests:Cu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and UV-VIS photoLab® 6600 (254/436nm)Further tests on demand, range information is based on max. area and can also be smaller for photoFlex®.
From CHF 99.80*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Tube tests NANOCOLOR® Nitrogen
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 164.30*

Photometers MD 110
Photometer for the analysis of determined parameters in drinking, industrial and waste water. Different models are available for common analyses as well as for special applications.Ergonomic, waterproof designAccurate, reproducible measurement resultsUser calibration and single point calibrationMeasurement results are displayed directly in ABS or %TZero value remains valid for all tests with the same sample thanks to the one-time zero (OTZ) functionAutomatic storage of measured values with time and date stamp and optional data transfer (IRiM module)Bluetooth® interfaceScroll memoryAutomatic shutdownAdjustment function displayScope of supply: Photometer, carrying case, reagents for 100 tests, cuvettes, batteries, standard accessoriesFurther photometers available on request.SpecificationsOptics:Highly precise interference filters, LEDWavelengths:530 / 560 / 610 / 430 / 580 / 660 nmWavelength accuracy:±1 nmPhotometric range: pH:0.005 A 6,5 - 8,4Data memory:16 measurementsDimensions (W x D x H):75 x 155 x 35 mmWeight:260 gPower supply:4 x AAA micro batteriesIP code:IP 68
From CHF 1,030.00*

Photometer PrimeLab 2.0 starter-kit, all parameters activated
The photometer with 18 different wavelengths (3 sensors with 6 wavelengths) covers the full VIS-spectrum as well as key parts of UV and IR spectrum. LEDs are set up at 180° as well as at 90° to enable NTU-Turbidity, PTSA and Fluorescein measurements as well.5.5" colour HD touch-displayMore than 140 different parameter methodsPlease order reagents separatelyAuto-calibration functionIntelligent OTZ (One-Time-Zero) functionCan be used with 1 ml, 16 mm and 24 mm cuvettesData management with free software (LabCOM) / app in free cloud including individual accounts and reporting systemScope of supply:Multitest Photometer PrimeLab 2.0, carrying case, 10 x 24 mm/10 ml glass cuvettes with lid, light-shield, 16 and 24 mm cuvette adapters, stirring rod, 10 ml plastic syringe, cleaning brush, battery-charger with USB-cable (type C), 20 ml luer lock syringe, filter adapter, 2 cans with 50 filter papers, 100 ml can with lidSpectral range:390 ... 950 nm, 18 wavelengthsAmbient temperature:5 ... 45 °CRel. humidity:30 ... 90 %Internal memory:150000 measurementsDatatransfer:WiFi, GSMSoftware:LabCOM software, LabCOM App, LabCOM CloudPower supply:8500 mA Li-Io battery, 5 V power supply with adaptersWarranty:2 years
From CHF 2,389.00*

Reagent sets drops
From CHF 19.80*