Spectrophotometer photoLab® 7100 VIS and photoLab® 7600 UV-VIS with OptRF

Description
COD measurement without reagents.
The spectrophotometer of the photoLab® 7000 Series are universally usable and offer complete photometric
functionality with lauded user-interface and guidance on a brilliant HD 7"" color display. Pioneering is the optical reagent-free measurement (OptRF) of COD, Nitrate and Nitrite. No time-consuming digestion and no harmful chemicals required.
  • Proven routine analysis for waste and drinking water, aquaculture, food & beverage, environmental monitoring and production
  • Cost saving reagent-free OptRF measurement
  • Universal for industrial, research and educational use
  • Lab quality in the field: 4,5 kg light weight, with car battery and field case option
  • Linking lab with Online-system WTW® IQ SENSORNET via IQ LabLink
  • For 16 mm round cuvettes and 10, 20 and 50 mm rectangular cuvettes with automatic recognition
  • Memory for 5000 values, spectra and kinetics approx. 40 MB, equivalent to approx. 500 spectra (300-900 nm) and 400 kinetics with 150 measured values
  • More than 200 programmed methods, 1000 user defined methods, 20 profiles each for kinetics and absorption spectrum, extensive programming options
Routine Analysis:
  • More than 250 programs for commercial test kits, standard parameters, direct readings of coloration, SAK, etc. as well as user-defined programming of routines
  • Barcode recognition for tests in vials and rectangular cells and automatic cell recognition for 16, 10, 20 and 50 mm without adapter and automatic measurement range selection
  • Up to three parallel timers
  • Optional PC-Software Package for Brewery and color measurement from CIE to Yellowness
Spectral and universal analysis from 190 to 1100 nm:
  • Spectral scans in various nm-steps, 700-2000 nm/min
  • Kinetics and multi-wavelength readings including special methods like chlorophyll and ADMI color measurement
  • Extensive programming tools for multistep and multi-wavelength functions with user guidance
AQA: Multi-level user-friendly AQA functions with administration tools and comprehensive checking aids for meter and reagents.
Data Management:
  • Measurement data, PDF documents, spectra and kinetics data, with data filter for pre-selected data management
  • External barcode reading option for uncoded test kits and sample ID
  • Optional: PC-Software for GLP compliant data management

Properties
Accuracy: ±1 nm
Accuracy: 1 nm
Depth: 314 mm
Dimensions (WxDxH): 404 x 314 x 197 mm
Height: 197 mm
IP code: IP 30
Illuminants: Tungsten-halogen
Interfaces: USB-A, USB-B, Ethernet
Manufacturer Article Number: 250203
Max. voltage: 240 V
Measuring method: VIS
Min. voltage: 100 V
Optical system: Split Beam
Photometric accuracy: ±0.003 E for E
Photometric measuring range: -3.300 ... 3.300 E
Power supply: 100 ... 240 V, 50/60 Hz
Power supply frequency: 50/60 Hz
Scattered light: < 0.1 %T (340/408 nm)
Spectral bandwidth: 4 nm
Type: photoLab® 7100 VIS
Type of auxiliary energy: Mains connection
UNSPSC: 41115406
Wavelength: 320 ... 1100 nm
Weight: 4.5 kg
Width: 404 mm
Skip product gallery

Accessories

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Accessories for spectrophotometer photoLab® 7100 VIS/7600 UV-VIS
From CHF 491.00*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Photometer MD50
Single-parameter photometer for analysing various parameters in water treatment. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable.Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsOne-point calibrationProgramming option for one customised methodNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupScope of supply: Photometer, 3 x 24 mm round glass cuvettes with lid and sealing ring, screwdriver, 3 x stirring rods, 10 ml syringe, cleaning brush, USB-C to USB-A cable, carrying case, 2 x AA batteries, operating instructions, reagents (depending on variant)
From CHF 595.00*

Photometer MD150 Cl-pH, with liquid reagents
Single-parameter photometer for analysing various parameters in water treatment. The innovative optics achieves fast, high-precision measurements. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable. Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsAbsorbance measurement possibleProgramming option for one customised methodOption to customise methods list based on reagent typeNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupMethods: M100, M101, M103, M110, M112, M330, M331Scope of supply: 3 x 24 mm vials with lid, 3 x stirring rods, syringe, cleaning brush, screwdriver, USB-C to USB-A cable, instruction manual, reagents, 2 x AA batteriesSingle-parameter photometer for analysing various parameters in water treatment. The innovative optics achieves fast, high-precision measurements. The device contains pre-programmed methods for different types of reagents. With the One-Time-Zero function, the device only needs to be zeroed once per sample. Data can be easily transferred to the AquaLX® app via NFC or to the PC software using a USB cable. Robust, ergonomic design with rubber-protected sides for a firm gripDisplay with coloured backlight shows the status of results and errorsLanguage-free user interface with icons and animationsAccurate and reproducible resultsAbsorbance measurement possibleProgramming option for one customised methodOption to customise methods list based on reagent typeNFC data transmissionUSB-C connectionAutomatic storage of the last 100 readings and protocols with time and date stampGLP compliant data backupMethods: M100, M101, M103, M110, M112, M330, M331Scope of supply: 3 x 24 mm vials with lid, 3 x stirring rods, syringe, cleaning brush, screwdriver, USB-C to USB-A cable, instruction manual, reagents, 2 x AA batteries
From CHF 861.90*

Photometer MD50 COD
The MD50 COD is specifically designed for COD determination and offers superior performance, enhanced usability and expanded testing capabilities, including the new Very Low Range (VLR) COD method for ultra-sensitive measurements.Highest accuracy for low-pollution samplesMeasurement of COD in high, medium and very low ranges for versatile applicationsEasy operation thanks to intuitive symbols and animations as well as user-friendly navigationResults within seconds enable high efficiencyTime saving with the One Time Zero function (stays valid for up to 8 hours)Handheld design for comfortable single-handed operationRobust housing with side protection for extra durabilityWireless NFC and USB-C data transferAutomatic GLP complianceVersatile connectivity via the AquaLX® app or Lovibond® Data Expert softwarePre-programmed Lovibond® CSB cuvette tests for operation right out of the box available separatelyMethods: M134, M130, M133, M131, M132Scope of supply: Photometer in carrying case, adapter for cells (16 mm), 2 x dosing syringes (1 ml, 2 ml), USB-C cable, screwdriver, manual, 2 x AA batteries
From CHF 550.00*