Skip to main content Skip to search Skip to main navigation
Menu

Stirring platforms OxiTop® for BOD measurement

Description
These Stirring platforms have been specially developed for BOD measurement with the OxiTop® system. Software-controlled speed regulation prevents the magnetic stirrer bar from getting caught or wobbling. The speed is selected so that an optimal gas exchange with the sample takes place. The stirrer is maintenance-free and non-wearing as it contains no moving parts.
The IS 6-Var model has been specially developed for use with large measuring vessels and has space for 6 measuring vessels. Its outer dimensions are identical to those of the IS 12. Speed 180 to 450 rpm.

Properties
Depth: 266 mm
Dimensions (WxDxH): 350 x 266 x 67 mm
Height: 67 mm
IP code: IP 30
Manufacturer Article Number: 208141
Max. voltage: 240 V
Min. voltage: 100 V
No. of measuring positions: 12
Power supply: 100 ... 240 V, 50/60 Hz
Power supply frequency: 50/60 Hz
Type: IS 12
Type of auxiliary energy: Mains connection
UNSPSC: 41-11-56-00
Weight: 3.2 kg
Width: 350 mm
Skip product gallery

Similar products

Dissolved oxygen bottles, Winkler pattern
Winkler pattern. Soda-lime glass.For determination of dissolved oxygen in water. The measured capacity is specified to ± 0,01ml. With white labelling area. Solid, bevelled glass stopper, secured with an accessory spring clip. Each bottle is adjusted to the relevant stopper. Stoppers and bottles are therefore not interchangeable. Each bottle and its stopper is marked with a unique, matching identification number.
From CHF 34.80*

Thermostatic cabinets TC, with steel door
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubatorThe incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubator
From CHF 2,565.00*

Overflow Measuring Flask for OxiTop®
Glass measuring flask with fixed volume doses for the easy and accurate measurement of the required sample volume for respirometric BSB measurements.
From CHF 68.30*

Controlled Temperature Cabinet TS 608/2-i for standard applications, 2 internal sockets
Compact temperature cabinets with internal sockets for the use of OxiTop® IS 12 stirring platforms.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.Compact temperature cabinets with internal sockets for the use of OxiTop® IS 12 stirring platforms.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.
From CHF 4,176.00*

Measuring heads OxiTop®-i, 1 measuring head
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsMenu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings
From CHF 722.00*

Measuring heads OxiTop®-i, 6 measuring heads Set 6
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readingsScope of supply: 3 x measuring head grey, 3 x measuring head blue, 6 sample bottles, 6 rubber quivers, 6 magnetic stirring rods
From CHF 3,912.00*