Skip to main content Skip to search Skip to main navigation
Menu

UV transilluminators

Description
Standard features include a high/low intensity safety switch and an efficient starter that allows each of the six 8W UV tubes to energise quickly without flickering, while special filter glass minimises unwanted background light. All of these features maximise contrast and sensitivity, allowing even the faintest fluorescent gels to be viewed.

Properties
Filter size mm: 210 x 210
Manufacturer Article Number: CSLUVTS312
Spare tubes Type: E
Tubes: 6 x 8W
Type: CSLUVTS312
UNSPSC: 41-10-53-04
Wavelength nm: 312
Skip product gallery

Similar products

Spare tubes for UV Instruments and UV Lamps
Suitable for all instruments from Vilber Lourmat.
From CHF 42.00*

UV lamps
Filtered and unfiltered(*) UV lamps with different wave lengths and power levels for a broad range of applicationsModels with wave length selector suited for multiple applicationsElectronic ballast (ECG), flicker-free, low-maintenanceFurther models on request.Note: please order lamp holder separately.
From CHF 711.00*

Compact UV transilluminators
Compact designMetal housing, with stainless steel filter frame and "long life" filterModern technology, highest quality manufactureSingle or dual wavelength models availableBECXF models have intensity selector (Hi/Lo)
From CHF 1,652.00*

Blue- and white light LED-Transilluminators
Powerful LED lighting arrays for blue (470 nm) and white (broad wavelength) illumination to image fluorescent and colorimetric gels. Through LED lights no ageing of UV bulbs and because of the inbuilt white LED array a separate white light table is not necessary. Well suited for teaching labs in universities and schools. Compatible with blue light excited safe DNA stains, as well as traditional stains such as ethidium bromide.Magnetic filter compatible with wide range of DNA stains3 level adjustable LED intensityBottom up illumination provides even sample illuminationAutomatic power-off to prevent heat build-upHigh quality aluminium housingScope of supply:Transilluminator, orange hinged filter, paper hoodSpecificationsWavelength:470 nm + white lightViewing size:120 x 180 mmDimensions (W x D x H):220 x 185 x 30 mmInput voltage:12 V, 2 APower supply:110 ... 240 V
From CHF 890.60*

Blue light LED transilluminators runVIEW MINI
The Mini-Blue light Transilluminator uses harmless blue light to illuminate both traditional Ethidium bromide stained gels as well as safe stains. Slotting under any gel tank, but perfect for our MINI and MIDI sized multiSUB gel tanks. With an orange filter window to visualize DNA in real time within gel tanks, it is perfect for quickly checking PCR fidelity and restriction digest results. The device can also be used as a stand-alone transilluminator with the gel placed directly on the illuminator.High intensity blue LED illuminator allows visualization of a wide range of fluorescent gel stainsCompatible with runSAFE, commercial safe stains and ethidium bromideScope of supply: Transilluminator, filter (orange)SpecificationsWavelength:470 nmViewing size:112 x 75 mmDimensions (W x D x H):86 x 170 x 25 mmWeight:338 gPower supply:DC 12 V, 2 A
From CHF 723.80*

Gel Documentation System Doc-Print CX3
Doc-Print CX3 is a stand-alone system with a small footprint that doesn't need a computer. The free VisionCapt software guarantees full GLP compliance. Molecular weight calculation, band quantification, colony counting, distance calculation, text annotations and image enhancement are included.Field of view: 24 x 18 cmScientific grade camera - Made in Germany3 megapixel resolution (extandable to 20 megapixels)Auto-exposure16-bit - 65 536 grey levelsPassive coolingUSB 3 connectionLarge 12.6" touchscreen interface displaySelf-understandable user interfacePrint or save on an external drive via the USB portConnection of a thermal printer possibleAll models include the following standard components: Imaging unit with touch display and software, camera, zoom objective, UV-/vis F-590 Filter and dark hood.
From CHF 9,019.00*

Gel documentation system microDOC with UV-Transilluminator
Recently upgraded with a new 24.1 megapixel digital CMOS camera to guarantee superb resolution, the microDOC is the researcher's choice for a simple ultra-compact gel documentation system that meets constraints in both budget and space within the laboratory. A large 8" TFT screen enables images, including agarose and fluorescent gels, colorimetric gels, autoradiography film and blotting membrane, to be captured clearly and easily. The system is computer-free and supplied with an 8 GB storage card and 58 mm ethidium bromide filter as standard, while an optional SYBR filter is also available. Files are saved onto the storage card in RAW, TIFF-RGB and JPEG formats and may be transferred to computer for analysis with the highly recommended TotalLab™ 1D software.microDOC BASIC: The microDOC BASIC is a simple low-cost system comprising a lift-off dark room hood and 24.1 megapixel digital camera, through which the gel is viewed directly. This system can be supplied with optional TotalLab™ 1D Analysis Software and any one of the 21 x 21cm transilluminators (please enquire).TotalLab™ 1D software: is supplied only as part of a complete package with each of the microDOC and transilluminator options. Its main functions include: lane creation, background subtraction, band detection, profile deconvolution, and molecular size, pI and quantity calibration. More sophisticated standalone software options are available for 1D applications that require band matching, array, colony counting and image ToolBox functionalities.Camera:File Format Design rule for Camera File system, DPOF (version 1.1) compliantFocus-Area Selection AF mode and manual focus are availableHoodMulti-Power Source for camera, Inner light lamp, TFT screen (excludes MicroDOC Basic/1D models)Safety Door Switch Automatically disconnects UV transilluminator, while opening the chamber door during operationwith Video and Audio InputSpecifications Camera:Effective Pixels: Type:24.1 megapixels TTL-CT-SIR with CMOS sensorLens:Canon EF/EF-S 18-55 mmMaximum Aperture:f/2.8 - f/5.6Image Resolution:720 × 480 up to 5,184 × 3,456Data Type Still images:Exif 2.3 (JPEG), RAW (CR2)Movies:MOV (Image data: H264 ; Audio data: Linear PCM (stereo))Filter: Inner White Light:Ethidium Bromide or SYBR Green (58 mm) 2 x 3 W white light LED (excl. MDOC Basic Models)Monitor: Display Format: Luminance:8" TFT liquid crystal screen 960 x 234 mm 300 cd/m2Display Mode:NTSC/PAL mode switchableDimensions with camera (W x D x H):290 x 325 x 515 mmRated Voltages: Weight approx.:110 - 220 V 7.7 kg* incl.Analysis Software TotalLab1D.
From CHF 2,920.00*

Gel documentation system gelONE-E
Gel documentation system with in built touch screen. The 20 x 24 cm imaging area means even large gels can be imaged with ease. Suitable for documentation of DNA-gels stained with EtBr and SYBR stains, AutoRads und Coomassie stained gels, tissues, slides and films. Images are captured using the built in software and saved direct to USB memory sticks for transfer to PC. The geneQUANT advanced image analysis package is included in the system license free.5 megapixel camera with low light sensitivityIn built 7" touch screenMotor driven zoom lensWhite LED lighting for sample positioningSafety switch prevents accidental UV exposureScope of supply:Darkroom, camera, UV transilluminator, imaging filter, license free geneQUANT advanced image analysis packageSpecificationsResolution:5 megapixelsLens:8 - 48 MM F/1.2Sensor bit-depth:12/16 bitGreyscales:65536Dynamic range:3.6/4.8 (extended)Transilluminator wavelength:302 nmTransilluminator size:200 x 240 mmDimensions (W x D x H):450 x 310 x 750 mmWeight:20 kgPower supply:230 V/50 Hz
From CHF 12,000.00*