Skip to main content Skip to search Skip to main navigation
Menu

VarioPrep preparative columns NUCLEODUR® 100-10 C18 ec, 10 µm

Description
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.

Octadecyl phases, 17.5 % C, particle size 10 µm

Properties
Carbon content: 17.5 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 10 mm
Length: 250 mm
Manufacturer Article Number: 762010.100
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Preparative
Particle size: 10 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L1
Volume column: 20 ml
pH stability: 1 ... 9
Skip product gallery

Accessories

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5, 100-7, 100-10 C18 ec
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.VarioPrep guard columns require a VP guard column holder.
From CHF 522.10*

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
VarioPrep guard column holders and replacement parts
VarioPrep columnscolumn system for preparative HPLC manufactured from stainless steel with two adjustable end fittings, allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column, packed with NUCLEODUR® and NUCLEOSIL® spherical silica.O-rings available on request.
From CHF 354.60*
Skip product gallery

Similar products

Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
From CHF 46.10*

HPLC Detector lamps
From CHF 635.00*

Preparative HPLC columns Nucleosil®100-5 C18
Grain size 5 µm, pore dia. 100 Å. Octadecyl phase, endcapped, 15 % C.
From CHF 399.10*

EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octyl phases, 10.5 % C, particle size 5 µm.
From CHF 297.30*

VarioPrep preparative columns NUCLEDUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octyl phases, 10.5 % C, particle size 5 µm.
From CHF 765.40*

EC analytical columns NUCLEODUR® 100-5
Totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0.9 ml/g, surface (BET) 340 m²/g, density 0.47 g/ml, pressure stability 800 bar, pH stability 2 - 8.Particle size 5 µm.
From CHF 439.40*

EC analytical columns NUCLEODUR® 100-5 CN, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column n-heptane, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 CN-RP, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column acetonitrile, particle size 5 µm
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 NH2, 5 µm
Pore size 110 Å, particle sizes 3 and 5 µm; 2.5 % C; not endcapped - USP L8Multi-mode columns (RP and NP):Normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesReversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsIon exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MSIdeal for:polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.Eluent in column n-heptane, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 NH2-RP, 5 µm
Pore size 110 Å, particle sizes 3 and 5 µm; 2.5 % C; not endcapped - USP L8Multi-mode columns (RP and NP):Normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesReversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsIon exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MSIdeal for:polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.Eluent in column acetonitrile, particle size 5 µm.
From CHF 415.40*