Skip to main content Skip to search Skip to main navigation
Menu

VarioPrep preparative columns NUCLEODUR® C18 Gravity

Description
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

Available as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.

  • Ideal for method development

  • Allows HPLC at pH extremes (pH 1 - 11)

  • Suitable for LC/MS due to low bleeding characteristics

  • Recommended for overall sophisticated analytical separations

  • Optimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressants

Particle size 5 µm, 18 % C

Properties
Carbon content: 18 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 10 mm
Length: 250 mm
Manufacturer Article Number: 762113.100
Material column: Silica gel
Max. temperature resistance: 60 °C
Method: Preparative
Particle size: 5 µm
Particle type: Fully porous
Separation system: Reverse phase
UNSPSC: 23-15-18-16
USP listing: L1
Volume column: 20 ml
pH stability: 1 ... 11
Skip product gallery

Accessories

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
VarioPrep guard column holders and replacement parts
VarioPrep columnscolumn system for preparative HPLC manufactured from stainless steel with two adjustable end fittings, allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column, packed with NUCLEODUR® and NUCLEOSIL® spherical silica.O-rings available on request.
From CHF 354.60*

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
VarioPrep guard columns NUCLEODUR® C18 Gravity
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsVarioPrep guard columns require a VP guard column holder.
From CHF 449.30*
Skip product gallery

Similar products

EC analytical columns NUCLEODUR® C18 Gravity, 1.8 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 1.8 µm, 18 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 3 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 3 µm, 18 % C.
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 5 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 5 µm, 18 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® C8 Gravity, 5 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 5 µm, 11 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® C8 Gravity, 1.8 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 1.8 µm, 11 % C.
From CHF 750.90*

EC analytical columns NUCLEOCEL DELTA-RP S, 5 µm
NUCLEOCEL DELTA enantiomer separation based on cellulose derivativesBase material silica,chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40Similar phases: Chiralcel® OD, Kromasil®, CelluCoat™, Eurocel® 01S-Type for high resolution, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi).Recommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds.NUCLEOCEL DELTA-RP for reversed phase applications:Eluent in column acetonitrile - water (40:60, v/v), particle size 5 µm. Designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchlorate.
From CHF 3,179.60*

Guard columns for EC columns NUCLEODUR® C18 Isis, 3 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsGuard columns for EC columns require the guard column adapter EC.
From CHF 241.30*

Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
From CHF 46.10*

Guard columns for NUCLEOGEL® SUGAR 810 Ca columns
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.
From CHF 709.00*

Guard columns for NUCLEOGEL® SUGAR 810 H columns
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.
From CHF 709.00*