Wireless module for WTW® measuring instruments | Type: IDS WLM-M

Wireless module for connecting to MultiLine® 3310/3510/36x0 IDS, inoLab® Multi IDS and MonoLine. Connects up to three sensors at the same time (depends on meter capabilities). Also for operation of OxiTop®-IDS.

Type: IDS WLM-M

Similar products

Dissolved oxygen bottles, Winkler pattern
Winkler pattern. Soda-lime glass.For determination of dissolved oxygen in water. The measured capacity is specified to ± 0,01ml. With white labelling area. Solid, bevelled glass stopper, secured with an accessory spring clip. Each bottle is adjusted to the relevant stopper. Stoppers and bottles are therefore not interchangeable. Each bottle and its stopper is marked with a unique, matching identification number.
From CHF 33.90*

Overflow Measuring Flask for OxiTop®
Glass measuring flask with fixed volume doses for the easy and accurate measurement of the required sample volume for respirometric BSB measurements.
From CHF 66.20*

Measuring heads OxiTop®-i
Menu-operated measuring heads. Output of the BOD measurement values directly on the display.3 operating buttonsBacklit graphic LCDControl LEDVolume pre-selectionMeasurement duration selectable (1 to 7 days)Display of measuring curveDisplay of current readings
From CHF 700.20*

Controlled Temperature Cabinets BOD
Compact temperature cabinets with internal plugs for the use of OxiTop® IS 12 stirring platforms. Models with insulation glass door allow for visual control of the OxiTop® heads without opening the door.Incubation conforming to standardsSuited for BOD, OECD 301F, soil respiration, anaerobic degradationTemperature adjustable in steps of 1 K between 10 and 40 °CEco-friendly refrigerant R600aNote: The necessary temperature constancy will only achieved in combination with the samples.TS 608/2i: Model for standard applications, with 2 internal plugs, incl. 2 shelvesTS 608-G/2i: As TS 608/2i, but with door made of insulation glassSpecificationsTemperature range:10 ... 40 °CIncrement:1 KTemperature stability:±0,5 K
From CHF 4,055.00*

BOD sensor system
Measuring systems for the reliable determination of 90 to 999 ppm BOD. Complete with sensor heads and multi-position magnetic stirrer.The sensor heads are screwed directly onto the BOD bottlesAutomatic storage of 5 results in 24-hour intervalsMeasured readings in mg/l (ppm) can be read directly on the sensor at any timeProtected against splashing water (IP 54)Scope of supply BOD sensor system 6: 6-position magnetic stirrer, each 6 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rodsScope of supply BOD sensor system 10: 10-position magnetic stirrer, each 10 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rodsSpecificationsBOD range:90 ... 999 ppmDisplay:LED (3 digits)IP code:IP 54
From CHF 272.00*

BOD-Measurement-System BD 600
BOD measurement is an important measurement of the effects of domestic and industrial waste water on sewage plants and outflow points. The sensor system BD 600 is a 6 sample system that allows precise measurements of BOD based on the manometric principle. Manometric respirometers relate oxygen uptake to the change in pressure caused by oxygen consumption while maintaining a constant volume. Due to the modern integral pressure sensors, it is not necessary to use mercury for the measurements. The BOD values are stored automatically in the sensor memory at regular intervals and can be called up on the large-format display at any time without the need for time-consuming conversion using factors. This means that test series that end on a Sunday can be evaluated during the following week without any problem. Measurement series can be stored on USB stick/ SD card or transferred via USB cable to evaluate the data on a computer. The measurement period is user-selectable between 1 and 28 days to suit the application. While short measurement periods are useful for scientific applications, standard BOD measurements typically extend over a period of 5 days - and manometric determination of OECD, for example, generally takes place over a period of 28 days.Scope of supply:BD 600, complete unit with 6 or 12* sensor heads and control unit with batteriesPower supply unit incl. Y-cable for common power supply of BD 600 and stirring unitInductive stirring unit6 or 12* sample bottles6 or 12* rubber gaskets6 or 12* magnetic stirring rods1 overflow flask, 157 ml1 overflow flask, 428 ml1 bottle, 50 ml potassium hydroxide solution1 bottle, 50 ml nitrification inhibitor solution1 instruction manualremote controlSpecificationsMeasuring principle:respirometric, electronic pressure sensorRanges:0 - 40, 0 - 80, 0 - 200, 0 - 400, 0 - 800, 0 - 2000, 0 - 4000 mg/l O2Measurement period:User-selectable, between 1 and 28 daysPower supply:100-240 V, battery buffered or via power supply using Y-cableProtection class:IP 54 (sensor head)Interface:USB host port (USB stick), USB device port (computer), SD cardClock:Real timeApplication:BOD5 / BODF / OECD301F* 6 or 12 depending on BOD-System (BD600 or BD606)
Price on request

Adapter AD/SK for BOD measuring system OxiTop®
For OxiTop® measuring heads, for all sample and measuring bottles series PF45/.. and MF45/.., autoclavable (121 °C). Incl. OxiTop® AD adapter, OxiTop® SK screwable adapter, DI45 gasket for adapter VS45.
From CHF 140.30*