Skip to main content Skip to search Skip to main navigation
Menu

Pitot tubes for testo differential pressure and climate measuring instruments

Description
Pitot tubes made of stainless steel for measuring the flow velocity.

Properties
For: testo 400 / 420 / 440 / 512-1 / 521-2
Length: 1000 mm
Manufacturer Article Number: 06352345
UNSPSC: 41-11-19-27
Ø: 7 mm
Skip product gallery

Similar products

Room climate monitor RM 100
For reliable control and evaluation of indoor air quality. Simultaneous measurement and display of temperature, CO2 concentration and humidity. The CO2 concentration in the air is additionally indicated by three LEDs as good, medium or bad.Alarming when limit is exceededLarge, illuminated displayFactory calibration certificateScope of supply: Room climate monitor RM 100, external AC/DC adapter
From CHF 194.30*

Climate measuring instruments testo 440
The climate measuring instruments testo 440 combine the benefits of a compact handheld device with intuitive measurement menus and a comprehensive selection of air velocity & IAQ probes. Both the digital Testo Smart Probes and numerous Testo temperature probes can be connected. Clearly structured menus for measuring volume flow in ducts/at outlets, degree of turbulence, cooling/heating load, mould indication and logging mode are stored on the instrument.The testo 440 dP also has an integrated differential pressure sensor. This makes measurements at filters as well as Pitot tube and K-factor measurements possible.USB interface for data export and optional printout of measuring valuesUp to 3 probes can be connectedParallel display of 3 measuring valuesBluetooth probes for measuring convenience and easy storage in the caseUniversal handle for all probesMeasurement of the following parameters are possible: °C, % r.h., CO, CO2, m/s, Lux, hPaPlease order probes separately.SpecificationsTemperature measuring range (NTC):-40 ... +150 °CAccuracy:±0.4 °C (-40 ... -25.1 °C) ±0.3 °C (-25 ... +74.9 °C) ±0.4 °C (+75 ... +99.9 °C) ±0.5 % of measured value (remaining range)Resolution:0.1 °CTemperature measuring range (TE Typ K):-200 ... +1370 °CAccuracy:±(0.3 °C + 0.3 % of measured value)Resolution:0.1 °CDifferential pressure measuring range testo 440 dP:-150 ... +1500 hPaAccuracy:±0.05 hPa (0 ... +1.00 hPa) ±0.2 hPa + 1.5 % of measured value (+1.01 ... +150 hPa)Resolution:0,01 hPaMemory:7500 measurement protocolsOperating / storage temperature:-20 ... +50 °CDimensions (W x D x H):65 x 32 x 154 mmWeight:250 gPower supply:3 x Mignon, Type AA
From CHF 621.00*

Sound level meter SU 130, class II
Sound level meter for noise measuring.Delivered in a hard carrying caseMulti measuring functions: Lp: Standard sound level measuring function, Leq: Energy equivalent sound level measuring mode (type A), Ln: Shows the deviation from a pre-defined limit in %Selectable methods of evaluation: A: As sensitive as the human ear, C: Sensitive for noisier environmental, conditions, where there are machines, plant, motors etc., F: For areas where sound intensity does not varyFunction to set limits: Programmable target value for go/no-go test valuesTrack function for continuous recording of variable environmental conditionsPeak Hold Mode to capture peaksInternal memory for measured values, for 30 measurements. Can be displayed on the PCData interface RS-232, included
From CHF 337.00*

Light measuring instrument testo 540
Quick and easy-to-use instrument for measuring lighting conditions in the workplace. The sensor is adapted to spectral sensitivity of the eye.Display illuminationHold-functionMax./min. valuesScope of supply: Meter incl. protection cap, batteries, calibration protocolSpecificationsMeasuring range:0 to 99999 lxResolution:1 lx (0 to 19999 lx) 10 lx (remaining range)Accuracy:±3 lx or ±3 %Measuring frequency:0.5 sDimensions (W x D x H):133 x 46 x 25 mmWeight:95 gIP code:IP 40Power supply:2 Micro cells AAA
From CHF 235.00*

CO2 Meter, Air CO2ntrol 3000
Large displayMeasuring range: 0 to 3000 ppmIncl. Power supply for 230 VAC24-hour data loggerAdjustable Alarm°C/°F-selectableRelay output for ventilation controlApplications: Ideal for monitoring the environment (CO2 concentration) in public buildings, such as universities, schools, for e.g. Hospitals, Education, Office, Production Plants, Public Facilities.SpecificationsCO2 range:0 ... 3000ppmResolution:1ppm (0 up to 1000ppm); 5ppm (1000 up to 2000ppm); 10ppm (2000ppm)Accuracy:50ppm or 5%, larger value appliesTemperaturerange:0 ... +50°CResolution:0,1°CAccuracy:±1% or 1°C, larger value appliesDisplay:7 segment LCD(twin-lined)Housing:Plastic (ABS)Supply requirements:230 VAC adapter or 4 x AA BatteriesDimensions:165 x 80 x 23mmWeight:600g (incl. packaging)
From CHF 350.00*

Pt100 Laboratory probes for testo measuring devices
Suitable for measurements in corrosive media. Ideal for use in laboratory and industry. Precise Pt100 sensor with replaceable glass coating and fixed cable.
From CHF 183.00*

Precision handheld instruments P700 series
For temperature, moisture and airflow.For highly accurate temperature measurements with USB PC online interface. (Optional: Windows SmartGraph software for graphical and tabular documentation, etc). Integral probe calibration for sensor tolerance compensation. Min.- Max.- Hold- and AVG- functions. The large LCD shows two measurements synchronously, even temperature differences can be displayed (P705, P755, P755-Log, P770).SpecificationsGeneral (all models):USB interface, Max-Min memory, Hold function, true average calculation over a freely selectable period, Auto-off function, measured quantities can be freely assigned to instrument channels, comprehensive calibration options (selectable 1-point, 2-point or 3-point calibration), large display with bar graph for simultaneous display of 2 measured valuesP700/P705:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S), measurement ranges and accuracies: Pt100:-200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types (-200 to +1760°C)P710/P715:1/2 measurement channels (Thermocouples type K, J, L, N, T), measurement ranges and accuracies: -200 to +1370°C (±0.2 °C from 0 to +200 °C, ±0.5 °C to 1000 °C, otherwise ± 1.0 °C of measurement value)Thermocouples acc. to EN 60584P750/P755/P755-Log:1/2 measurement channels (Pt100 4-wire probe, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C (±0.03°C -50 to +200°C, ±0.05°C -200 to +200°C, otherwise ±0.05% of measurement value), thermocouples, DIN type (types J, K, L, N, T 0 to 200 °C, ±0.3°C, +200 to +1000°C ±1.0 °C, otherwise ±1.5°C;type R, S ±1.0 °C +0.1% of measurement value) humidity 0 to 100% R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value +1.0% of final value)P770:2 measurement channels (Pt100, thermocouples type J, K, L, N, T, R, S, moisture, flow), measurement ranges and accuracies: Pt100: -200 to +850°C ( ±0.1 °C -100 to +200°C, otherwise ±0.1% of measurement value)thermocouples, DIN types, humidity 0 to 100%R.H. ( ±1.5%R.H.), flow 0 to 40 m/s (±0.5% of measurement value)Dimensions (L x W x D)/ weight: 200 x 85 x 40mm / 300gP700-P755 for Ex-use Zone 1 and Zone 2 according to ATEX approval II 2 G Ex ib IIB T4 Gb available on request.
From CHF 320.00*

Cases for climate measuring devices testo 440
For storing and transporting the climatic measuring device testo 440 and additional probes.
From CHF 132.00*

Probes for climate measuring instrument testo 440
Digital probes with intelligent calibration concept. All probe heads can be easily attached to the universal handle.
Price on request